华西口腔医学杂志 ›› 2020, Vol. 38 ›› Issue (1): 95-100.doi: 10.7518/hxkq.2020.01.017
收稿日期:
2019-03-21
修回日期:
2019-09-19
出版日期:
2020-02-01
发布日期:
2020-02-06
通讯作者:
邓文正
E-mail:13977416853@139.com
作者简介:
王晓华,住院医师,硕士,E-mail: 1437546057@qq.com
基金资助:
Wang Xiaohua1,2,Liu Aipeng1,Deng Wenzheng1()
Received:
2019-03-21
Revised:
2019-09-19
Online:
2020-02-01
Published:
2020-02-06
Contact:
Wenzheng Deng
E-mail:13977416853@139.com
Supported by:
摘要:
牙种植是修复缺失牙齿的主要方法之一。精确的植入位置是实现功能性和美观性修复的基础。数字化导板可将术前规划的虚拟种植体位置精确地转移到实际种植手术部位,是实现最佳种植的重要载体。本研究对数字化导板的发展与制作、分类、优缺点、精确性影响因素等进行阐述,以期提高种植手术的精确性。
中图分类号:
王晓华,刘艾芃,邓文正. 数字化导板在口腔种植中的研究进展[J]. 华西口腔医学杂志, 2020, 38(1): 95-100.
Wang Xiaohua,Liu Aipeng,Deng Wenzheng. Research advances in the use of digital surgical guides in implantology[J]. West China Journal of Stomatology, 2020, 38(1): 95-100.
[1] | Albrektsson T, Johansson C . Osteoinduction, osteoconduction and osseointegration[J]. Eur Spine J, 2001,10(Suppl 2):S96-S101. |
[2] | Tahmaseb A, Wu V, Wismeijer D , et al. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis[J]. Clin Oral Implant Res, 2018,29(S16):416-435. |
[3] | Tatakis DN, Chien HH, Parashis AO . Guided implant surgery risks and their prevention[J]. Periodontol 2000, 2019,81(1):194-208. |
[4] | Fürhauser R, Mailath-Pokorny G, Haas R , et al. Esthetics of flapless single-tooth implants in the anterior maxilla using guided surgery: association of three-dimensional accuracy and pink esthetic score[J]. Clin Implant Dent Relat Res, 2015,17(Suppl 2):e427-e433. |
[5] | Garcia-Hammaker S, George FM . Use of a surgical template for minimally invasive second-stage surgery: a dental technique[J]. J Prosthet Dent, 2019,121(1):37-40. |
[6] | Kaufmann R, Bassetti R, Mericske-Stern R , et al. Enlargement of keratinized peri-implant mucosa at the time of second stage surgery (re-entry)[J]. Swiss Dent J, 2014,124(12):1315-1331. |
[7] | Naziri E, Schramm A, Wilde F . Accuracy of computer-assisted implant placement with insertion templates[J]. GMS Interdiscip Plast Reconstr Surg DGPW, 2016. DOI: 10.3205/iprs000094. |
[8] | D’haese J, van De Velde T, Komiyama A , et al. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature[J]. Clin Implant Dent Relat Res, 2012,14(3):321-335. |
[9] | Schwindling FS, Hilgenfeld T, Weber D , et al. In vitro diagnostic accuracy of low-dose CBCT for evaluation of peri-implant bone lesions[J]. Clin Oral Impl Res, 2019,30(12):1200-1208. |
[10] | Schnutenhaus S, Gröller S, Luthardt RG , et al. Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: a prospective controlled clinical study[J]. Clin Implant Dent Relat Res, 2018,20(4):541-549. |
[11] | Jacobs R, Quirynen M . Dental cone beam computed tomography: justification for use in planning oral implant placement[J]. Periodontol 2000, 2014,66(1):203-213. |
[12] | Schwarz MS, Rothman SL, Rhodes ML , et al. Computed tomography: partⅠ. Preoperative assessment of the mandible for endosseous implant surgery[J]. Int J Oral Maxillofac Implants, 1987,2(3):137-141. |
[13] | Chan HL, Misch K, Wang HL . Dental imaging in implant treatment planning[J]. Implant Dent, 2010,19(4):288-298. |
[14] | Kaewsiri D, Panmekiate S, Subbalekha K , et al. The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: a randomized controlled trial[J]. Clin Oral Implants Res, 2019,30(6):505-514. |
[15] | Smitkarn P, Subbalekha K, Mattheos N , et al. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery[J]. J Clin Periodontol, 2019,46(9):949-957. |
[16] | Sammartino G, Valle AD, Marenzi G , et al. Stereolithography in oral implantology: a comparison of surgical guides[J]. Implant Dent, 2004,13(2):133-139. |
[17] | Peng YT, Tseng CC, Du YC , et al. A novel conversion method for radiographic guide into surgical guide[J]. Clin Implant Dent Relat Res, 2017,19(3):447-457. |
[18] | Matta RE, Bergauer B, Adler W , et al. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template[J]. J Craniomaxillofac Surg, 2017,45(6):804-808. |
[19] | Pozzi A, Polizzi G, Moy PK . Guided surgery with tooth-supported templates for single missing teeth: a critical review[J]. Eur J Oral Implantol, 2016,9(Suppl 1):S135-S153. |
[20] | Ochi M, Kanazawa M, Sato D , et al. Factors affecting accuracy of implant placement with mucosa-supported stereolithographic surgical guides in edentulous mandibles[J]. Comput Biol Med, 2013,43(11):1653-1660. |
[21] | D’Souza KM, Aras MA . Types of implant surgical guides in dentistry: a review[J]. J Oral Implantol, 2012,38(5):643-652. |
[22] | Stumpel LJ 3rd . Cast-based guided implant placement: a novel technique[J]. J Prosthet Dent, 2008,100(1):61-69. |
[23] | Kühl S, Zürcher S, Mahid T , et al. Accuracy of full guided vs. half-guided implant surgery[J]. Clin Oral Implants Res, 2013,24(7):763-769. |
[24] | Bencharit S, Staffen A, Yeung M , et al. In vivo tooth-supported implant surgical guides fabricated with desktop stereolithographic printers: fully guided surgery is more accurate than partially guided surgery[J]. J Oral Maxillofac Surg, 2018,76(7):1431-1439. |
[25] | Scherer U, Stoetzer M, Ruecker M , et al. Template-guided vs. non-guided drilling in site preparation of dental implants[J]. Clin Oral Investig, 2015,19(6):1339-1346. |
[26] | Shen P, Zhao JY, Fan LF , et al. Accuracy evaluation of computer-designed surgical guide template in oral implantology[J]. J Craniomaxillofac Surg, 2015,43(10):2189-2194. |
[27] | Verhamme LM, Meijer GJ, Boumans T , et al. A clinically relevant accuracy study of computer-planned implant placement in the edentulous maxilla using mucosa-supported surgical templates[J]. Clin Implant Dent Relat Res, 2015,17(2):343-352. |
[28] | Schimmel M, Müller F, Suter V , et al. Implants for elderly patients[J]. Periodontol 2000, 2017,73(1):228-240. |
[29] | Vieira DM, Sotto-Maior BS, Barros CA , et al. Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches[J]. Int J Oral Maxillofac Implants, 2013,28(5):1347-1351. |
[30] | Cassetta M . Immediate loading of implants inserted in edentulous arches using multiple mucosa-supported stereolithographic surgical templates: a 10-year prospective cohort study[J]. Int J Oral Maxillofac Surg, 2016,45(4):526-534. |
[31] | Bashutski JD, Wang HL, Rudek I , et al. Effect of flapless surgery on single-tooth implants in the esthetic zone: a randomized clinical trial[J]. J Periodontol, 2013,84(12):1747-1754. |
[32] | Derksen W, Wismeijer D, Flügge T , et al. The accuracy of computer-guided implant surgery with tooth-supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study[J]. Clin Oral Impl Res, 2019,30(10):1005-1015. |
[33] | Vasak C, Kohal RJ, Lettner S , et al. Clinical and radiological evaluation of a template-guided (NobelGuide™) treatment concept[J]. Clin Oral Implants Res, 2014,25(1):116-123. |
[34] | Schnutenhaus S, Edelmann C, Rudolph H , et al. 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study[J]. Clin Oral Investig, 2018,22(6):2363-2372. |
[35] | Vercruyssen M, Fortin T, Widmann G , et al. Different techniques of static/dynamic guided implant surgery: modalities and indications[J]. Periodontol 2000, 2014,66(1):214-227. |
[36] | Yeung M, Abdulmajeed A, Carrico CK , et al. Accuracy and precision of 3D-printed implant surgical guides with different implant systems: an in vitro study[J]. J Prosthet Dent, 2019. DOI: 10.1016/j.prosdent.2019.05.027. |
[37] | Chen ZZ, Li JY, Sinjab K , et al. Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery: a cadaver study[J]. Clin Oral Implants Res, 2018,29(12):1186-1194. |
[38] | Block MS, Emery RW . Static or dynamic navigation for implant placement-choosing the method of guidance[J]. J Oral Maxillofac Surg, 2016,74(2):269-277. |
[39] | Somogyi-Ganss E, Holmes HI, Jokstad A . Accuracy of a novel prototype dynamic computer-assisted surgery system[J]. Clin Oral Implants Res, 2015,26(8):882-890. |
[40] | Vercruyssen M, Hultin M, van Assche N , et al. Guided surgery: accuracy and efficacy[J]. Periodontol 2000, 2014,66(1):228-246. |
[41] | Zhou WJ, Liu ZH, Song LS , et al. Clinical factors affecting the accuracy of guided implant surgery: a systematic review and meta-analysis[J]. J Evid Based Dent Pract, 2018,18(1):28-40. |
[42] | Ozan O, Orhan K, Turkyilmaz I . Correlation between bone density and angular deviation of implants placed using CT-generated surgical guides[J]. J Craniofac Surg, 2011,22(5):1755-1761. |
[43] | Turbush SK, Turkyilmaz I . Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study[J]. J Prosthet Dent, 2012,108(3):181-188. |
[44] | Ozan O, Turkyilmaz I, Ersoy AE , et al. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement[J]. J Oral Maxillofac Surg, 2009,67(2):394-401. |
[45] | Yatzkair G, Cheng A, Brodie S , et al. Accuracy of computer-guided implantation in a human cadaver model[J]. Clin Oral Impl Res, 2015,26(10):1143-1149. |
[46] | El Kholy K, Lazarin R, Janner SFM , et al. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery[J]. Clin Oral Impl Res, 2019,30(11):1067-1075. |
[47] | Vercruyssen M, Cox C, Coucke W , et al. A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template[J]. J Clin Periodontol, 2014,41(7):717-723. |
[48] | D’haese J, Ackhurst J, Wismeijer D , et al. Current state of the art of computer-guided implant surgery[J]. Periodontol 2000, 2017,73(1):121-133. |
[49] | Pettersson A, Komiyama A, Hultin M , et al. Accuracy of virtually planned and template guided implant surgery on edentate patients[J]. Clin Implant Dent Relat Res, 2012,14(4):527-537. |
[50] | Cristache CM, Gurbanescu S . Accuracy evaluation of a stereolithographic surgical template for dental implant insertion using 3D superimposition protocol[J]. Int J Dent, 2017. DOI: 10.1155/2017/4292081. |
[51] | Naziri E, Schramm A, Wilde F . Accuracy of computer-assisted implant placement with insertion templates[J]. GMS Interdiscip Plast Reconstr Surg DGPW, 2016. DOI: 10.3205/iprs000094. |
[52] | Tallarico M, Kim YJ, Cocchi F , et al. Accuracy of newly developed sleeve-designed templates for insertion of dental implants: a prospective multicenters clinical trial[J]. Clin Implant Dent Relat Res, 2019,21(1):108-113. |
[53] | Lee JH, Park JM, Kim SM , et al. An assessment of template-guided implant surgery in terms of accuracy and related factors[J]. J Adv Prosthodont, 2013,5(4):440-447. |
[54] | Rungcharassaeng K, Caruso JM, Kan JY , et al. Accuracy of computer-guided surgery: a comparison of operator experience[J]. J Prosthet Dent, 2015,114(3):407-413. |
[55] | Marei HF, Abdel-Hady A, Al-Khalifa K , et al. Influence of surgeon experience on the accuracy of implant placement via a partially computer-guided surgical protocol[J]. Int J Oral Maxillofac Implants, 2019,34(5):1177-1183. |
[56] | Arisan V, Karabuda ZC, Pişkin B , et al. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part Ⅱ: reliability of mucosa-supported stereolithographic guides[J]. Clin Implant Dent Relat Res, 2013,15(6):907-917. |
[57] | Ye NS, Long H, Xue JJ , et al. Integration accuracy of laser-scanned dental models into maxillofacial cone beam computed tomography images of different voxel sizes with different segmentation threshold settings[J]. Oral Surg Oral Med Oral Pathol Oral Radiol, 2014,117(6):780-786. |
[58] | Schneider D, Marquardt P, Zwahlen M , et al. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry[J]. Clin Oral Implants Res, 2009,20(Suppl 4):73-86. |
[59] | Noharet R, Pettersson A, Bourgeois D . Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides: a pilot study in the human cadaver[J]. J Prosthet Dent, 2014,112(3):526-532. |
[60] | Cassetta M, Di Mambro A, Giansanti M , et al. How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide[J]. Int J Oral Maxillofac Surg, 2014,43(1):85-92. |
[1] | 王良涛, 李珊, 陆豆豆, 陈铮. 基于正交试验梯度多孔牙种植体结构的设计研究[J]. 华西口腔医学杂志, 2023, 41(6): 647-652. |
[2] | 严鑫淼, 孙桃兰, 卢雨航, 谭馨, 王卓, 李淼晶. 基于机器学习的四川省12岁儿童龋齿预测模型[J]. 华西口腔医学杂志, 2023, 41(6): 686-693. |
[3] | 张隽婧, 张煜强, 范琳, 于海洋. 应用数字化流体树脂注射导板快速关闭正畸后前牙间隙1例[J]. 华西口腔医学杂志, 2023, 41(1): 114-122. |
[4] | 于海洋, 孙蔓琳, 王中熠. 前牙种植基台的临床决策——Lights决策树[J]. 华西口腔医学杂志, 2022, 40(5): 504-512. |
[5] | 杨雷宁, 秦行林, 张静, 韩晓鹏. 目标修复体空间指导多学科联合治疗精准修复1例[J]. 华西口腔医学杂志, 2022, 40(5): 610-617. |
[6] | 吴侃, 李巍铭, 钟亦思, 程立, 唐甜, 尹伟. 成都市社区中老年人口腔健康相关生活质量评价及其影响因素分析[J]. 华西口腔医学杂志, 2022, 40(4): 440-445. |
[7] | 林超, 张心怡, 田洪雨, 栾可峰, 孙昊, 范欣. 潍坊市7~8岁儿童口腔卫生服务利用影响因素研究[J]. 华西口腔医学杂志, 2022, 40(2): 197-203. |
[8] | 高羽轩, 汪鎏, 傅裕杰, 杨帆, 张岚, 黄定明. 数字化导板引导技术辅助微创治疗前牙钙化根管[J]. 华西口腔医学杂志, 2022, 40(1): 111-122. |
[9] | 孙国芳, 吴侃, 胡涛, 包崇云, 钟亦思, 尹伟. 成都市社区居民对口腔家庭医生服务模式签约意愿及其影响因素分析[J]. 华西口腔医学杂志, 2022, 40(1): 80-85. |
[10] | 范震, 刘月, 王佐林. 牙列缺失倾斜种植设计[J]. 华西口腔医学杂志, 2021, 39(4): 377-385. |
[11] | 陈益燕, Pradan Siras Prasad, 杨锦波. 302例显微根尖手术的回顾性研究[J]. 华西口腔医学杂志, 2021, 39(4): 458-463. |
[12] | 常乐, 徐静晨, 王翔宇, 陈嵩. 太原市养老机构老年人口腔健康状况的调查分析[J]. 华西口腔医学杂志, 2021, 39(2): 175-181. |
[13] | 张佳丽, 姚军, 仁青措姆, 许元泓. 西藏昌都市3~5岁儿童龋病及其影响因素调查分析[J]. 华西口腔医学杂志, 2021, 39(1): 53-57. |
[14] | 周洁, 甘雪琦, 卢嘉仪, 范林莉, 朱卓立. 牙种植体作支抗局部正畸直立近中倾斜下颌第二磨牙1例[J]. 华西口腔医学杂志, 2020, 38(6): 708-711. |
[15] | 李晓梅, 鲍济波, 谢志刚. 二次骨劈开技术在下颌狭窄牙槽嵴中的应用研究[J]. 华西口腔医学杂志, 2020, 38(3): 338-342. |
阅读次数 | ||||||
全文 |
|
|||||
摘要 |
|
|||||