华西口腔医学杂志

• 临床研究 • 上一篇    下一篇

Beagle犬后牙解剖特点与微螺钉种植体植入部位的相关研究

吕影涛 徐平平 元佩燕 王晶 许曼波   

  1. 南方医科大学附属口腔医院·广东省口腔医院口腔颌面外科, 广州510280
  • 收稿日期:2011-06-25 修回日期:2011-06-25 出版日期:2011-06-20 发布日期:2011-06-20
  • 通讯作者: 徐平平,Tel:020-84403311
  • 作者简介:吕影涛(1984—),男,河南人,硕士
  • 基金资助:

    广东省自然科学基金资助项目(8151026003000008)

Research on anatomy of posterior tooth in the Beagle dog and mini-screw implant implantation

Lv Yingtao, XU Ping -ping, YUAN Pei -yan, WANG Jing, XU Man -bo   

  1. Dept. of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southern Medical University & Guangdong Provincial Stomatological Hospital, Guangzhou 510280, China
  • Received:2011-06-25 Revised:2011-06-25 Online:2011-06-20 Published:2011-06-20
  • Contact: XU Ping -ping,Tel:020-84403311

摘要:

目的对Beagle犬后牙行解剖形态学观察和测量研究,为微螺钉种植体(MSI)在Beagle犬后牙根分叉区的植入提供相关参考数据。方法对5只Beagle犬后牙区70颗牙齿的实体标本行大体观察,并对根分叉区行相关解剖学测量。测量方法:首先描记出各牙齿牙体长轴,在牙冠上取与牙体长轴垂直的最大近远中径AB,过上颌后牙近中尖或下颌后牙中央尖C作与AB垂直且等长的线段CD(D点拟作为实验植入MSI的参照点),分别测量D点至近中根、远中根、根分叉的距离Dm、Dd、Df。结果实验所用Beagle犬左右侧同名牙Dm、Dd、Df值差异均无统计学意义(P>0.05)。各牙位各指标的测量值均服从正态分布,各牙位Dd值与Dm值基本相等,Df值均大于4 mm。结论D点可以作为MSI在Beagle犬后牙根分叉区植入的参考点。MSI以D点为参照点向近远中移动一定的距离即可达到接触或损伤牙根的目的。本研究结果可为支抗生物力学及稳定性的动物实验研究中MSI的植入提供一定的参考,也可为在牙根损伤修复动物实验研究中MSI植入时的定位提供参考依据。

关键词: 微螺钉种植体, Beagle犬, 解剖, 测量

Abstract:

Objective The morphological characteristics of posterior tooth in the Beagle dog were investigated in order to provide reference to mini-screw implant(MSI) implantation in the root furcation site. Methods Seventy posterior teeth of five Beagle dogs were collected and measured as follows: First, the greatest mesio-distal diameter AB of 1the crown was measured, which was  endicular to the tooth long axis. Second, mesial cusp of maxillary posterior tooth or central cusp of mandibular was marked as the piont C, and CD which was equal and perpendicular to AB was drawn. The piont D was planned to be the reference point for MSI implantation. Finally, Dm, Dd and Df were measured, which were the distance from the point D to the mesial and distal root surface and root furcation. Results The difference between the left and right sides teeth with the same name had no statistical significant(P>0.05). The measurement results of all indices assumed a Gaussian distribution. The mean Dd was basically equal to Dm. All the average Df were more than 4 mm. Conclusion The point D could be used as a reference point for MSI implantation in the root furcation site of posterior tooth in the Beagle dog. The data of this study can provide certain reference for MSI implantation in the study of the biomechanics of anchorage stability, and provide certain reference for MSI implantation in the study of root repair after injury.

Key words: mini-screw implant, Beagle dog, anatomy, measurement