华西口腔医学杂志 ›› 2021, Vol. 39 ›› Issue (3): 341-346.doi: 10.7518/hxkq.2021.03.015

• 修复学专栏 • 上一篇    下一篇

陶瓷材料对瓷贴面修复四环素牙光学性能的影响

陈瑾1,2(), 夏绮1, 张玲玲1, 钱慧芬3, 李星星1,2()   

  1. 1.昆明医科大学口腔医学院,昆明 650500
    2.昆明医科大学附属口腔医院口腔修复科,昆明 650100
    3.云南省第二人民医院口腔修复科,昆明 650021
  • 收稿日期:2020-03-16 修回日期:2021-01-29 出版日期:2021-06-01 发布日期:2021-05-26
  • 通讯作者: 李星星 E-mail:chenjin150525@163.com;xingxing2005099@163.com
  • 作者简介:陈瑾,住院医师,硕士,E-mail:chenjin150525@163.com
  • 基金资助:
    2017年国家级大学生创新训练项目(201710678011);云南省卫生和计划生育委员会医学后备人才基金资助项目(H-201638)

Effect of ceramic materials on the optical properties of porcelain veneers for tetracycline-stained teeth

Chen Jin1,2(), Xia Qi1, Zhang Lingling1, Qian Huifen3, Li Xingxing1,2()   

  1. 1.College of Stomatology, Kunming Medical University, Kunming 650500, China
    2.Dept. of Prosthodontics, Affiliated Stomatological Hospital of Kunming Medical University, Kunming 650100, China
    3.Dept. of Prosthodontics, The Second People's Hospital of Yunnan Province, Kunming 650021, China
  • Received:2020-03-16 Revised:2021-01-29 Online:2021-06-01 Published:2021-05-26
  • Contact: Li Xingxing E-mail:chenjin150525@163.com;xingxing2005099@163.com
  • Supported by:
    National Innovation Training Program for College Students(201710678011);The Medical Reserve Talent Projects in Yunnan Province(H-201638)

摘要: 目的

分析不同陶瓷材料瓷贴面在四环素牙背景下的色彩学性能和半透性。

方法

采用热压铸造和分层堆塑方法分别制作总厚度0.50 mm的A1、A3、B2、B4色玻璃陶瓷贴面和长石质瓷贴面试件各10片,利用分光光度计测量试件在模拟四环素牙背景及黑白背景上的L*、a*、b*值,计算试件在模拟四环素牙背景上与背景颜色的色差ΔE001、与试件在白背景上色差ΔE002及试件的TP值。

结果

IPS d.SIGN遮色长石质瓷试件的ΔE001显著大于IPS e.max Press LT玻璃陶瓷试件,B4色瓷试件的ΔE001显著大于其他色号(P<0.05)。遮色长石质瓷试件ΔE002均小于1.25,玻璃陶瓷试件ΔE002均大于2.23,但各颜色组间差异无统计学意义(P>0.05)。遮色长石质瓷试件TP值显著小于玻璃陶瓷(P<0.05),不同陶瓷颜色组间差异无统计学意义(P>0.05)。

结论

0.50 mm厚IPS d.SIGN遮色长石质瓷贴面美白改色四环素牙可获得理想的色彩学性能,但其半透性不理想,远差于IPS e.max Press LT玻璃陶瓷贴面。

关键词: 四环素牙, 瓷贴面, 玻璃陶瓷, 长石质瓷, 色差

Abstract: Objective

To analyze the chromatic properties and translucency of porcelain veneers made from different ceramic materials against the background of tetracycline-stained teeth.

Methods

Porcelain specimens (A1, A3, B2, B4) measuring 0.50 mm in thickness were prepared by heat-press casting and layering. The L*, a*, and b* values of the specimens against simulated tetracycline tooth and black-and-white backgrounds were measured by a spectrophotometer, and color differences ΔE001 between specimens on simulated tetracycline backgrounds and the backgrounds themselves and ΔE002 between specimens on simulated tetracycline backgrounds and the white background were calculated. The translucent parameter (TP) was also evaluated.

Results

The ΔE001 of feldspathic specimens (IPS d.SIGN) with the opaque layer was significantly greater than that of glass ceramic specimens (IPS e.max Press LT), and the ΔE001 of group B4 was consistently greater than those of the other color groups (P<0.05). The ΔE002 values of all feldspathic specimens with the opaque layer were less than 1.25, and the ΔE002 values of the glass ceramic specimens were greater than 2.23. However, no significant difference was observed among the different color groups (P>0.05). The TP values of feldspathic specimens with the opaque layer were significantly lower than those of glass ceramic specimens(P<0.05), but no significant difference was observed among different color groups (P>0.05).

Conclusion

When changing the color of tetracycline-stained teeth, 0.50 mm-thick IPS d.SIGN feldspathic veneers with an opaque layer provide better chromatic properties than IPS e.max Press LT glass ceramic veneers. However, the translucency of feldspathic veneers is generally poorer than that of glass ceramic veneers.

Key words: tetracycline-stained teeth, porcelain veneer, glass-ceramic, feldspathic ceramic, color difference

中图分类号: