华西口腔医学杂志

• 临床研究 • 上一篇    下一篇

粘固剂色调及厚度对Solidex树脂颜色的影响

邢文忠1, 王贻宁2, 陈小冬1   

  1. 1.大连市口腔医院修复科, 辽宁大连116021; 2.武汉大学口腔医院修复科, 湖北武汉430079
  • 收稿日期:2007-04-25 修回日期:2007-04-25 出版日期:2007-04-20 发布日期:2007-04-20
  • 通讯作者: 邢文忠, Tel:0411- 81247266
  • 作者简介:邢文忠(1976-),男,辽宁人,主治医师,硕士

Effect of the Shade and Thickness of Luting Agent on the Color of Solidex Resin

XING Wen - zhong1, WANG Yi- ning2, CHEN Xiao- dong1   

  1. 1. Dept. of Prosthodontics, Dalian Stomatological Hospital, Dalian 116021, China; 2. Dept. of Prosthodontics, College of Stomatology, Wuhan University, Wuhan 430079, China
  • Received:2007-04-25 Revised:2007-04-25 Online:2007-04-20 Published:2007-04-20
  • Contact: XING Wen - zhong, Tel:0411- 81247266

摘要:

目的研究粘固剂的色调、厚度变化对Solidex树脂试样颜色的影响。方法将不同厚度(0.1、0.2 mm)及色调(A1、A3)的粘固剂放于不同底色材料(镍铬合金、A3和C3色调的充填性树脂、遮色瓷饰面的镍铬合金)与不同厚度(0.5、1.0 、1.5 mm)的Solidex树脂试样之间,使用ShadeEye NCC测色仪测定Solidex树脂试样的颜色,计算在相同底色材料下,Solidex树脂试样采用不同厚度和色调粘固剂时的色差(△E*)。结果粘固剂的色调、厚度变化对Solidex树脂试样表面色差△E*均有显著影响,并且这种影响受到试样厚度、底色材料的交互作用(P<0.001)。粘固剂厚度变化中,A3色调粘固剂对0.5 mm厚度Solidex树脂试样表面颜色的色差△E*>2,为临床所不可接受。粘固剂色调变化中,0.2 mm厚度粘固剂对0.5 mm和1.0 mm厚Solidex树脂试样的色差△E*>2。结论粘固剂的色调及厚度变化可明显改变较薄的Solidex树脂试样表面颜色。

关键词: 复合树脂, 粘固剂, 颜色, 厚度

Abstract:

Objective To evaluate the effect of the shade and thickenss of luting agent on the final color of different  thickness Solidex resin in vitro. Methods Five specimens of Solidex resin were fabricated at thickness of 0.5, 1.0 and 1.5 mm. The pieces of Ni- Cr alloy, two shade composite resin and opaque porcelain veneered Ni- Cr alloy were used as backgrounds. The CIE L*a*b* values of specimens were measured by a colorimeter(ShadeEye NCC) to determine the colorimetric difference, when different thickness of specimens were overlaid the different shade and thickness of luting agent at the same backgrounds. Results The final color difference of specimens was significantly influenced by the factors of luting agent and the interaction of specimens thickness, backgrounds and luting agent(P< 0.001). Regarding the thickness of luting agent, A3 shade luting agents produced clinically unacceptable difference (△E*>2)in the final color of Solidex specimens at the thickness of 0.5 mm. Regarding the shade of luting agent, the color difference was more than 2 when the Solidex specimens at the thickness of 0.5 mm or 1.0 mm were against the 0.2 mm thick luting agent. Conclusion The final color of thinner Solidex specimens was significant affected by the change of the shade and thick of luting agent.

Key words: composite resin, luting agent, color, thickness