华西口腔医学杂志

• 临床研究 • 上一篇    下一篇

脉冲Nd:YAG激光根管内照射与牙根表面温度变化的关系

贺慧霞,刘鲁川,宋远雄,安建平   

  1. 400042 第三军医大学附属大坪医院口腔科
  • 收稿日期:2002-08-25 修回日期:2002-08-25 出版日期:2002-08-20 发布日期:2002-08-20
  • 基金资助:
    本课题为重庆市科委资助项目(编号2001-54-21)

A Study on the Effects of Pulsed Nd:YAG Laser Irradiation in Root Canal on Root Surface Temperature

He Huixia,Liu Luchuan, Song Yuanxiong,et al   

  1. Department ofStomatology, DapingHospital&Research Institute ofSurgery, the ThirdMilitaryMedicalUniversity
  • Received:2002-08-25 Revised:2002-08-25 Online:2002-08-20 Published:2002-08-20

摘要:

目的:探讨不同剂量的脉冲Nd:YAG激光根管内照射与牙根表面温度变化的关系及影响因素。方法:108颗离体单根管牙处理后分为3组。A组为同剂量激光根管内照射不同牙位的牙;B、C两组分别在15 Hz和20 Hz频率下分7种功率根管内照射,B组根管壁涂增效剂后再照射,测牙根表面中部的温度;C组加测根表面下部的温度。结果:¹同剂量激光根管内照射,下切牙较上切牙、尖牙和前磨牙根面温度显著升高(P<0101)。º20 Hz和15 Hz 照射组随激光功率增大牙根表面温度升高。»根管壁涂增效剂后各功率激光照射后根面升温显著增加(P< 0101)。¼同剂量激光照射,根尖部较根管中部温度升高更多。结论:在一定范围内,脉冲Nd:YAG激光根管内照射,牙根表面温度变化随功率、频率增大而增加;牙位和增效剂等对牙根表面温度变化有不同程度影响。

关键词: 脉冲Nd:YAG激光, 照射剂量, 牙根表面, 温度测定

Abstract:

Objective:The purpose of this studywas to evaluate the effects of the pulsed Nd:YAG laserirradiation in root canals on tem- perature changes on the root surface in vitro and optimize the parameters of laser irradiation in root canal treatment.Methods:A total of 108 extracted single-root human teeth were divided into A, B and C groups, after the preparation of root canals and re- moval of their crowns. GroupAwas evaluated the surface temperature changes of differentteeth irradiatedwith the same outputen- ergy. The teeth inGroup B and Cwere irradiated respectivelywith the frequencies of 15 Hz and 20 Hz, and 7 differentoutput en- ergy, and the inner root canal surface inGroup Bwas coatedwith a layerof ink, whichworked as the initiator.Results:The tooth surface temperature of the mandibular incisor increased more obviously than that of the maxillary incisor, canine and premolar, during root canal irradiation treatment (P<0101). Significant difference was shown on the temperature elevation when the teeth were irradiated with 2W or higher output power (P<0101). Temperature increased significantly higher in the teeth with initiator than thatwithout it (P<0101). With the same parameters of output energy, the surface temperature demonstrated higher on the apical partof the root canal than thatin the middle.Conclusion:There is significantly positive correlation between the temperature elevation on the root surface and the average output power and frequency of the pulsed Nd:YAG laserirradiation in the root canal. The shape of tooth, initiator and different parts of the root may also play important roles in the temperature changes of the tooth surface. This study may help optimize the parameters of clinical laser irradiation treatment.

Key words: rootcanaltreatment, pulsedNd:YAGlaserirradiation, rootsurfacetemperature