West China Journal of Stomatology ›› 2024, Vol. 42 ›› Issue (3): 372-381.doi: 10.7518/hxkq.2024.2023387
• Implantology • Previous Articles Next Articles
Ren Bihui(), Xu Yehao, Dai Jieting, Guo Shuigen, Wei Hongwu(
)
Received:
2023-11-17
Revised:
2024-02-04
Online:
2024-06-01
Published:
2024-05-24
Contact:
Wei Hongwu
E-mail:1282127248@qq.com;nc.whw@163.com
CLC Number:
Ren Bihui, Xu Yehao, Dai Jieting, Guo Shuigen, Wei Hongwu. Experimental study on implant-abutment locking force and abutment subsidence in a pure Morse taper connection implant system[J]. West China Journal of Stomatology, 2024, 42(3): 372-381.
Add to citation manager EndNote|Ris|BibTeX
Tab 2
Implant-abutment locking forces and their magnitude of change under different loading forces
锁结柱直径/mm | 锁结深度/mm | 锁结力/N | P值 | 锁结力变化幅度/% | 相关系数R | ||
---|---|---|---|---|---|---|---|
加载200 N | 加载300 N | 加载400 N | |||||
2.5 | 1.0 | 182.15±10.60* | 220.67±10.14* | 312.45±21.72* | 0.000 | 41.70 | 0.941 |
2.0 | 190.14±14.16* | 286.44±16.81* | 343.94±23.33* | 0.000 | 44.72 | 0.954 | |
3.0 | 187.50±14.42* | 295.10±12.68* | 353.96±14.71* | 0.000 | 47.03 | 0.968 | |
3.0 | 1.0 | 164.55±15.25* | 247.06±30.59* | 316.00±14.74* | 0.000 | 47.93 | 0.949 |
2.0 | 192.60±9.87* | 289.30±20.84* | 367.80±27.22* | 0.000 | 47.63 | 0.963 | |
3.0 | 189.75±18.99* | 262.60±34.84* | 380.22±9.20* | 0.000 | 50.10 | 0.953 | |
3.5 | 1.0 | 186.06±11.94* | 252.00±15.77* | 316.00±14.74* | 0.000 | 41.12 | 0.969 |
2.0 | 199.28±17.15* | 289.17±19.00* | 367.80±27.22* | 0.000 | 45.82 | 0.977 | |
3.0 | 206.30±10.70* | 315.05±7.20* | 406.15±14.84* | 0.000 | 49.21 | 0.990 |
Tab 3
Implant-abutment locking force and its magnitude of change at different locking depths
实验机加载力/N | 锁结柱直径/mm | 锁结力/N | P值 | 锁结力变化幅度/% | 相关系数R | ||
---|---|---|---|---|---|---|---|
锁结深1.0 mm | 锁结深2.0 mm | 锁结深3.0 mm | |||||
200 | 2.5 | 182.15±10.60 | 190.14±14.16 | 187.50±14.42 | 0.398 | 4.20 | 0.169 |
3.0 | 164.55±15.25* | 192.60±9.87* | 189.75±18.99* | 0.000 | 14.56 | 0.538 | |
3.5 | 186.06±11.94* | 199.28±17.15 | 206.30±10.70 | 0.008 | 9.81 | 0.538 | |
300 | 2.5 | 220.67±10.14* | 286.44±16.81 | 295.10±12.68 | 0.000 | 25.22 | 0.853 |
3.0 | 247.06±30.59* | 289.30±20.84 | 262.60±34.84 | 0.011 | 14.60 | 0.193 | |
3.5 | 252.00±15.77* | 289.17±19.00* | 315.05±7.20* | 0.000 | 20.65 | 0.874 | |
400 | 2.5 | 312.45±21.72* | 343.94±23.33 | 353.96±14.71 | 0.000 | 11.73 | 0.649 |
3.0 | 316.00±14.74* | 367.80±27.22 | 380.22±9.20 | 0.000 | 16.89 | 0.795 | |
3.5 | 316.00±14.74* | 367.80±27.22* | 406.15±14.84* | 0.000 | 22.20 | 0.854 |
Tab 4
Implant-abutment locking force and its variation with different locking post diameters
锁结深度/mm | 实验机加载力/N | 锁结力/N | P值 | 锁结力变化幅度/% | 相关系数R | ||
---|---|---|---|---|---|---|---|
锁结柱直径2.5 mm | 锁结柱直径3.0 mm | 锁结柱直径3.5 mm | |||||
1.0 | 200 | 182.15±10.60 | 164.55±15.25* | 186.06±11.94 | 0.002 | 11.56 | 0.104 |
300 | 220.67±10.14* | 247.06±30.59 | 252.00±15.77 | 0.005 | 12.43 | 0.533 | |
400 | 312.45±21.72 | 316.00±14.74 | 316.00±14.74 | 0.871 | 1.13 | 0.087 | |
2.0 | 200 | 190.14±14.16 | 192.60±9.87 | 199.28±17.15 | 0.337 | 4.59 | 0.269 |
300 | 286.44±16.81 | 289.30±20.84 | 289.17±19.00 | 0.930 | 0.99 | 0.062 | |
400 | 343.94±23.33* | 367.80±27.22 | 367.80±27.22 | 0.000 | 6.49 | 0.698 | |
3.0 | 200 | 187.50±14.42 | 189.75±18.99 | 206.30±10.70* | 0.019 | 9.11 | 0.463 |
300 | 295.10±12.68 | 262.60±34.84* | 315.05±7.20 | 0.000 | 16.65 | 0.272 | |
400 | 353.96±14.71* | 380.22±9.20* | 406.15±14.84* | 0.000 | 12.85 | 0.862 |
Tab 5
Abutment subsidence and its magnitude of change under different test loading forces
锁结柱直径/mm | 锁结深度/mm | 基台下沉量/mm | P值 | 下沉量变化幅度/% | 相关系数R | ||
---|---|---|---|---|---|---|---|
加载200 N | 加载300 N | 加载400 N | |||||
2.5 | 1.0 | 0.36±0.04 | 0.38±0.05 | 0.47±0.02* | 0.000 | 23.40 | 0.757 |
2.0 | 0.31±0.03* | 0.33±0.02* | 0.41±0.02* | 0.000 | 24.39 | 0.857 | |
3.0 | 0.22±0.02* | 0.24±0.01* | 0.30±0.02* | 0.000 | 26.67 | 0.872 | |
3.0 | 1.0 | 0.36±0.04 | 0.38±0.06 | 0.42±0.02* | 0.015 | 19.05 | 0.505 |
2.0 | 0.32±0.03 | 0.31±0.02 | 0.37±0.02* | 0.000 | 13.51 | 0.611 | |
3.0 | 0.24±0.02 | 0.29±0.11 | 0.30±0.02 | 0.181 | 20.00 | 0.041 | |
3.5 | 1.0 | 0.33±0.03* | 0.38±0.05* | 0.43±0.05* | 0.000 | 23.26 | 0.724 |
2.0 | 0.26±0.04* | 0.29±0.02* | 0.34±0.03* | 0.000 | 14.71 | 0.738 | |
3.0 | 0.20±0.03* | 0.27±0.05 | 0.30±0.04 | 0.000 | 33.33 | 0.701 |
Tab 6
Abutment subsidence and its magnitude at different locking depths
实验机加载力/N | 锁结柱直径/mm | 基台下沉量/mm | P值 | 下沉量变化幅度/% | 相关系数R | ||
---|---|---|---|---|---|---|---|
锁结深1.0 mm | 锁结深2.0 mm | 锁结深3.0 mm | |||||
200 | 2.5 | 0.36±0.04* | 0.31±0.03* | 0.22±0.02* | 0.000 | 38.89 | -0.871 |
3.0 | 0.36±0.04* | 0.32±0.03* | 0.24±0.02* | 0.000 | 33.33 | -0.406 | |
3.5 | 0.33±0.03* | 0.26±0.04* | 0.20±0.03* | 0.000 | 39.39 | -0.856 | |
300 | 2.5 | 0.38±0.05* | 0.33±0.02* | 0.24±0.01* | 0.000 | 36.84 | -0.864 |
3.0 | 0.38±0.06* | 0.31±0.02 | 0.29±0.11 | 0.029 | 23.68 | -0.845 | |
3.5 | 0.38±0.05* | 0.29±0.02 | 0.27±0.05 | 0.000 | 28.95 | -0.742 | |
400 | 2.5 | 0.47±0.02* | 0.41±0.02* | 0.30±0.02* | 0.000 | 36.17 | -0.963 |
3.0 | 0.42±0.02* | 0.37±0.02* | 0.30±0.02* | 0.000 | 28.57 | -0.928 | |
3.5 | 0.43±0.05* | 0.34±0.03* | 0.30±0.04* | 0.000 | 30.23 | -0.787 |
Tab 7
Abutment subsidence and its magnitude of change for different locking column diameters
锁结深度/mm | 实验机加载力/N | 基台下沉量/mm | P值 | 下沉量变化幅度/% | 相关系数R | ||
---|---|---|---|---|---|---|---|
锁结柱直径2.5 mm | 锁结柱直径3.0 mm | 锁结柱直径3.5 mm | |||||
1.0 | 200 | 0.36±0.04 | 0.36±0.04 | 0.33±0.03 | 0.115 | 8.33 | -0.294 |
300 | 0.38±0.05 | 0.38±0.06 | 0.38±0.05 | 0.974 | 0.00 | -0.042 | |
400 | 0.47±0.02* | 0.42±0.02 | 0.43±0.05 | 0.004 | 10.64 | -0.421 | |
2.0 | 200 | 0.31±0.03 | 0.32±0.03 | 0.26±0.04* | 0.003 | 18.75 | -0.474 |
300 | 0.33±0.02* | 0.31±0.02 | 0.29±0.02 | 0.001 | 12.12 | -0.616 | |
400 | 0.41±0.02* | 0.37±0.02* | 0.34±0.03* | 0.000 | 17.07 | -0.777 | |
3.0 | 200 | 0.22±0.02 | 0.24±0.02 | 0.20±0.03* | 0.004 | 16.67 | -0.145 |
300 | 0.24±0.01 | 0.29±0.11 | 0.27±0.05 | 0.382 | 17.24 | 0.291 | |
400 | 0.30±0.02 | 0.30±0.02 | 0.30±0.04 | 0.747 | 0.00 | -0.043 |
Tab 8
Implant-abutment locking force and abutment subsidence at different implant wall thicknesses
实验机加载力/N | 锁结深度/mm | 锁结力/N | P值 | 基台下沉量/mm | P值 | ||
---|---|---|---|---|---|---|---|
外壁厚0.15 mm | 外壁厚0.30 mm | 外壁厚0.15 mm | 外壁厚0.30 mm | ||||
200 | 1.0 | 182.60±17.00 | 189.50±12.61 | 0.316 | 0.33±0.03 | 0.24±0.03 | 0.000 |
2.0 | 199.28±17.15 | 207.85±14.65 | 0.245 | 0.26±0.04 | 0.19±0.03 | 0.000 | |
3.0 | 206.30±10.70 | 210.35±20.16 | 0.582 | 0.20±0.03 | 0.18±0.05 | 0.045 | |
300 | 1.0 | 252.00±15.77 | 271.85±12.87 | 0.006 | 0.38±0.05 | 0.28±0.04 | 0.000 |
2.0 | 289.17±19.00 | 280.40±8.63 | 0.201 | 0.29±0.02 | 0.25±0.03 | 0.001 | |
3.0 | 315.05±7.20 | 293.05±23.52 | 0.011 | 0.27±0.05 | 0.20±0.04 | 0.002 | |
400 | 1.0 | 316.00±14.74 | 345.04±18.95 | 0.001 | 0.43±0.05 | 0.30±0.05 | 0.000 |
2.0 | 396.35±17.73 | 369.85±21.16 | 0.007 | 0.34±0.03 | 0.30±0.04 | 0.019 | |
3.0 | 406.15±14.85 | 383.60±24.19 | 0.022 | 0.30±0.04 | 0.23±0.03 | 0.002 |
1 | Romanos GE, Delgado-Ruiz R, Sculean A. Concepts for prevention of complications in implant therapy[J]. Perio-dontol 2000, 2019, 81(1): 7-17. |
2 | Lang NP, Pun L, Lau KY, et al. A systematic review on survival and success rates of implants placed immediately into fresh extraction sockets after at least 1 year[J]. Clin Oral Implant Res, 2012, 23(): 39-66. |
3 | Schmitt CM, Nogueira-Filho G, Tenenbaum HC, et al. Performance of conical abutment (Morse Taper) connection implants: a systematic review[J]. J Biomed Mater Res A, 2014, 102(2): 552-574. |
4 | Machado LS, Bonfante EA, Anchieta RB, et al. Implant-abutment connection designs for anterior crowns: relia-bility and failure modes[J]. Implant Dent, 2013, 22(5): 540-545. |
5 | Ricomini Filho AP, Fernandes FS, Straioto FG, et al. Preload loss and bacterial penetration on different implant-abutment connection systems[J]. Braz Dent J, 2010, 21(2): 123-129. |
6 | do Nascimento C, Miani PK, Pedrazzi V, et al. Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions[J]. Int J Oral Maxillofac Implants, 2012, 27(3): 551-560. |
7 | Pessoa RS, Sousa RM, Pereira LM, et al. Bone remode-ling around implants with external hexagon and morse-taper connections: a randomized, controlled, split-mou-th, clinical trial[J]. Clin Implant Dent Rel Res, 2017, 19(1): 97-110. |
8 | 汤初凉, 赵世凯, 黄翠. 莫氏锥度连接在口腔种植中的应用特点及研究进展[J]. 中华口腔医学杂志, 2017, 52 (1): 59-62. |
Tang CL, Zhao SK, Huang C. Features and advances of Morse taper connection in oral implant[J]. Chin J Stomatol, 2017, 52(1): 59-62. | |
9 | 龚金梅, 夏勋, 胡常琦, 等. 单纯锥度固位外连接种植体在前牙区窄牙槽嵴中应用的临床观察[J]. 华西口腔医学杂志, 2022, 40(2): 175-182. |
Gong JM, Xia X, Hu CQ, et al. Clinical observation of a narrow alveolar ridge in the anterior area with a simple taper retention implant[J]. West China J Stomatol, 2022, 40(2): 175-182. | |
10 | Liu Y, Wang JW. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck[J]. Arch Oral Biol, 2017, 83: 153-160. |
11 | Chu CM, Huang HL, Hsu JT, et al. Influences of internal tapered abutment designs on bone stresses around a dental implant: three-dimensional finite element method wi-th statistical evaluation[J]. J Periodontol, 2012, 83(1): 111-118. |
12 | Baixe S, Fauxpoint G, Arntz Y, et al. Microgap between zirconia abutments and titanium implants[J]. Int J Oral Maxillofac Implants, 2010, 25(3): 455-460. |
13 | Gao WM, Geng W, Luo CC. Prosthetic complications of fixed dental prostheses supported by locking-taper implants: a retrospective study with a mean follow-up of 5 years[J]. BMC Oral Health, 2021, 21(1): 476. |
14 | Ribeiro MCO, Vargas-Moreno VF, Gomes RS, et al. Implant-supported crowns with locking taper implant-abutment connection: a systematic review and meta-analysis[J]. J Prosthet Dent, 2022: S0022-3913(22)00379-1. |
15 | 王美青. 口腔解剖生理学[M]. 7版. 北京: 人民卫生出版社, 2012: 439. |
Wang MQ. Oral anatomy and physiology[M]. 7th ed. Beijing: People's Medical Publishing House, 2012: 439. | |
16 | 周哲, 于婉琦, 杨诗卉, 等. 人天然牙的力学性能及其影响因素研究进展[J]. 实用口腔医学杂志, 2022, 38(2): 259-262. |
Zhou Z, Yu WQ, Yang SH, et al. Progress in the study of mechanical properties of human natural teeth and their influencing factors[J]. J Pract Dent, 2022, 38(2): 259-262. | |
17 | Ferrario VF, Sforza C, Serrao G, et al. Single tooth bite forces in healthy young adults[J]. J Oral Rehabil, 2004, 31(1): 18-22. |
18 | Shoji Y, Yusof MYPM, Idris RIB, et al. Bite force of patients with tooth pain[J]. Clin Exp Dent Res, 2022, 8(5): 1213-1217. |
19 | Moon SJ, Kim HJ, Son MK, et al. Sinking and fit of abutment of locking taper implant system[J]. J Adv Pro-sthodont, 2009, 1(2): 97-101. |
20 | Stenio Cardoso R, Sheyla Viana O, Sarita Pires V, et al. Morse taper internal connection implants: would abutment reseating influence retention[J]. Braz J Oral Sci, 2015, 14(3): 209-213. |
[1] | Chen Yunyi, Sun Ciji, Li Hong. Effects of flapless and flapped implantations on soft tissue: a systematic review and Meta-analysis [J]. West China Journal of Stomatology, 2024, 42(3): 382-393. |
[2] | Wang Liangtao, Li Shan, Lu Doudou, Chen Zheng.. Structural design of gradient porous dental implant based on orthogonal test [J]. West China Journal of Stomatology, 2023, 41(6): 647-652. |
[3] | Bangcheng Yang,Xuedong Zhou,Haiyang Yu,Yao Wu,Chongyun Bao,Yi Man,Lei Cheng,Yao Sun. Advances in titanium dental implant surface modification [J]. West China Journal of Stomatology, 2019, 37(2): 124-129. |
[4] | Lei Cheng,Haiyang Yu,Yao Wu,Chongyun Bao,Bangcheng Yang,Yi Man,Yao Sun,Xiaoli Yan,Xuedong Zhou. A review of peri-implant microbiology [J]. West China Journal of Stomatology, 2019, 37(1): 7-12. |
[5] | Ye. Lin. Current dental implant design and its clinical importance [J]. West China Journal of Stomatology, 2017, 35(1): 18-28. |
[6] | Wang Maiquan, Peng Liwei, Li Yunfeng. Efficacy of systemic administration of oxytocin on implant osseointegration in osteoporotic rats [J]. West China Journal of Stomatology, 2016, 34(4): 332-335. |
[7] | WANGXiao-jie, LUO Jiao-ming, CHENJi-yong, ZHANG Xing-dong. The Study on Three-dimension Finite Element Analysis of the Stress Distribution in the Mandible Bone around Dental Implants [J]. West China Journal of Stomatology, 2005, 23(02): 167-169. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||