Abstract:

Objective To assess the effect of the thickness of periodontal ligament on the fracture resistance of root and post- core system. Methods Forty- five simulated roots in the same length, taper and diameter were made of polymethacrylate(PMMA). Then the wax patterns of post- cores were cast. Soft lining material was used to simulated periodontal ligament. And each specimen was embedded in acrylic resin and then fixed in a special jig on the universal load- testing machine. A compressive load was applied at a 90- degree angle to the long axis of the core until fracture, at a crosshead speed of 1 mm/min. The maximum of load and the displacement were recorded. Results The mean values of load in root and post- core system were 148.033 N、161.889 N、168.667 N、181.589 N、194.622 N, and the mean values of displacement were 1.965 mm、2.837 mm、3.327 mm、3.927 mm、5.326 mm. Conclusion The fracture resistance and displacement of root and post- core system with the same quality and altitude periodontal ligament are associated with the thickness of periodontal ligament when the range of thickness is from 0.2 mm to
1.0 mm.

Key words: thickness of periodontal ligament, root and post- core system, fracture resistance, displacement