West China Journal of Stomatology ›› 2020, Vol. 38 ›› Issue (1): 108-113.doi: 10.7518/hxkq.2020.01.020

Previous Articles    

Precise implant insertion technology for measuring dental implant placement

Jia Luming,He Jinxiu,Lu Jiayi,Yu Ping,Guo Jia,Fan Lin,Liu Chunxu,Yu Haiyang()   

  1. State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthetics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
  • Received:2019-05-20 Revised:2019-11-06 Online:2020-02-01 Published:2020-02-06
  • Contact: Haiyang Yu E-mail:yhyang6812@scu.edu.cn
  • Supported by:
    The National Natural Science Foundation of China(81571006)

Abstract:

Identifying the ideal implantation site is important for the long-term stability and effectiveness of follow-up restorations. Implant surgical guide and navigation are used to determine the implantation site in clinic and improve the precision of implantation. However, due to difficulties in digital methods, such as multiple procedures, high cost, and actual accuracy of more than 1 mm, many physicians still prefer to operate with free hand. In preoperative, intraoperative, and postoperative procedures, time-saving and practical methods for implant site evaluation are lacking. In many cases, oral physicians found that the position deviates only by cone beam CT, which was costly to modify the position. In this article, we presented a precise implantation insertion technology that is guided by a measurable technique throughout the implantation application for all implant systems. This method was guided by a dynamic control measuring ruler, which functions together with the measuring and intraoperative locating rulers. The 3D space of the operative area was measured by a measuring ruler prior to operation, and the implant plan and quantitative guidance design were conducted according to the measured and cone beam CT data. The whole implantation process was guided by the dynamic control measuring ruler, and measuring verification results were also considered. This method can realize the quantification of the entire preoperative space analysis, intraoperative precise implantation guidance, and postoperative site measurement and evaluation. This practical technique also helps to adjust the position, improve the implantation accuracy and is suitable in generalizing dental implantation.

Key words: oral implant surgery, precise implant insertion, real-time measurable, implantation site, analytical rulers, intraoperative locating rulers

CLC Number: