The influence of gilt to the retention of the complete metal crown

ZHANG Xiao-jun, SHI Lian-shui, ZHU Hong-shui   

  1. Dept. of Prosthetics, Stomatological Hospital, Nanchang University, Nanchang 330006, China
  • Received:2008-10-25 Revised:2008-10-25 Online:2008-10-20 Published:2008-10-20
  • Contact: SHI Lian-shui,Tel:0791-6086218

Abstract:

Objective To research the influence of gilt to the retention of the complete metal crown. Methods Sixty Ni-Cr alloy complete metal crown were divided into three groups, control group(common Ni-Cr alloy complete metal crown), whole gold-plating group(whole gilding on the tissue surface of the inner Ni-Cr alloy complete metal crown), partial gold-plating group(gilding on the tissue surface of 1/3 cervical inner Ni-Cr alloy complete metal crown). The retention force of complete metal crown was measured by tensile force/pressure ergograph. Results The retention force of control group, partial gold -plating group, whole gold -plating group were (657 ± 151) N, (632±139)N, (569±103)N, respectively. There were significant differences between control group and whole goldplating group, whole gold-plating group and partial gold-plating group(P<0.05). There was no significant difference between control group and partial gold -plating group(P >0.05). Conclusion The force of retention would de - crease after gilding on the tissue surface of the inner Ni-Cr alloy complete metal crown, but have no influence to normal retention requirement of complete crown. Although the retention of partial gold-plating complete metal crown had somewhat decrease, it could be ignored.

Key words: Ni-Cr alloy, gilt, complete metal crown, retention