West China Journal of Stomatology

Previous Articles     Next Articles

Construction of the Thr ee - dimensional Finite Element Model of Micro - implant - maxilla

DENG Feng1, ZHANG Lei2, ZHANG Yi2, SONG Jin- lin2, FAN Yu- bo1   

  1. 1. Biomechanical Engineering Laboratory, College of Architecture and Environics, Sichuan University, Chengdu 610044, China; 2. Dept. of Orthodontics, Affiliated Hospital of Stomatology, Chongqing University of Medical Sciences, Chongqing 400015, China
  • Received:2007-04-25 Revised:2007-04-25 Online:2007-04-20 Published:2007-04-20
  • Contact: FAN Yu- bo,Tel:13520075501

Abstract:

Objective To explore a new method to construct the three- dimensional finite element model of microimplant- maxilla using Materialise′s interactive medical image control system(Mimics). Methods The maxilla with all teeth was scanned with Spiral CT and the images were transferred into the Mimics 9.0 software to obtain the threedimensional images. The Abaqus 6.5 software was used to mesh the three- dimensional model and to establish the finite element model. Results A detachable three- dimensional finite element model of micro- implant- maxilla based on Mimics was constructed rapidly, which can be flexibly re- assembled. Conclusion The method of constructing the three- dimensional finite element model of micro- implant- maxilla is available and effective. The geometrical analogy of the model was greatly improved by using the Mimics system.

Key words: three- dimensional finite element, micro- implant, anchorage, Mimics software