West China Journal of Stomatology ›› 2021, Vol. 39 ›› Issue (6): 732-738.doi: 10.7518/hxkq.2021.06.018

Previous Articles    

Immediate precision of the digital osteotomy template in the digital stackable template: a clinical study

Lu Jiayi(), Yu Jiayi, Xie Chenyang, Gao Jing, Yu Haiyang()   

  1. State Key Laboratory of Oral Diseases & National Clinical Research Center of Oral Diseases & Dept. of Prosthetics, West China Hospital of Stomatology, Chengdu 610041, China
  • Received:2020-07-28 Revised:2021-03-11 Online:2021-12-01 Published:2021-12-03
  • Contact: Yu Haiyang E-mail:lujiayi2018@126.com;yhyang6812@scu.edu.cn
  • Supported by:
    Sichuan Provincial Science and Technology Department Fundation(2020YFS0040)

Abstract: Objective

This study aimed to evaluate the immediate accuracy of the digital osteotomy template in the digital stackable template.

Methods

From November 2018 to January 2020, 4 patients with dentition loss were selected from the Prosthodontics Department, West China Stomatological Hospital. All patients met the conditions for immediate planting and immediate restoration. Owing to the lack of vertical target-restoration space, the implantation plan included intraoperative osteotomy. According to the preoperative cone beam CT (CBCT) data, combined with aesthetic digital smile design (DSD) analysis, virtual wax design, and so on, the ideal bone plane design was performed. According to the virtual osteotomy plane, the virtual implantation plan was designed, and then the digital stackable template assuming osteotomy template, implantation guide, and temporary restoration were made and 3D printed. Osteotomy was performed under the guidance of digital osteotomy template during the operation. The preoperative CBCT and postoperative CBCT of all patients overlapped, the deviation between the actual osteotomy and the ideal osteotomy was calculated, and the angle deviation between the postoperative bone plane and the ideal bone plane was measured.

Results

The ave-rage volume deviation between the postoperative design and the ideal one was 492.94 mm³, accounting for 21.21% of the preset osteotomy volume. The average deviation between the postoperative osteotomy and the ideal osteotomy in four patients was 0.024 8 mm. The average angle between the postoperative bone plane and the ideal bone plane was 6.03°.

Conclusion

The displacement deviation of virtual osteotomy design and the actual osteotomy one under the guidance of digital osteotomy template in the digital stackable template are highly consistent with the original design. Thus, this clinical technique is worth popularizing, accurate, and quantifiable.

Key words: digital stackable template, implant supported fixed dental prothesis, vertical target restoration space

CLC Number: