West China Journal of Stomatology ›› 2020, Vol. 38 ›› Issue (2): 170-176.doi: 10.7518/hxkq.2020.02.011
Previous Articles Next Articles
Lou Fangzhi1, Zhang Maorui1, Rao Pengcheng1, Luo Shihong1, Tang Mengying1, Xiao Jingang1,2()
Received:
2019-05-11
Revised:
2019-08-16
Online:
2020-04-01
Published:
2020-04-15
Contact:
Jingang Xiao
E-mail:drxiaojingang@163.com
Supported by:
CLC Number:
Lou Fangzhi, Zhang Maorui, Rao Pengcheng, Luo Shihong, Tang Mengying, Xiao Jingang. Precise investigation of digital guide plates applied to implant surgery of anterior teeth[J]. West China Journal of Stomatology, 2020, 38(2): 170-176.
Add to citation manager EndNote|Ris|BibTeX
[1] | Rousseau P . Flapless and traditional dental implant surgery: an open, retrospective comparative study[J]. J Oral Maxillofac Surg, 2010,68(9):2299-2306. |
[2] | Kazor CE, Al-Shammari K, Sarment DP , et al. Implant plastic surgery: a review and rationale[J]. J Oral Implantol, 2004,30(4):240-254. |
[3] | 袁治, 陈一晖 . 计算机辅助设计导板修复上颌后种植体头部和角度偏离不影响种植体的植入精度[J]. 中国组织工程研究, 2016,20(20):2933-2939. |
Yuan Z, Chen YH . Implantation accuracy is not affected by head and angle deviation following computer aided design guide for repair of maxillary posterior tooth defects[J]. J Clin Rehabil Tissue Eng Res, 2016,20(20):2933-2939. | |
[4] | Block MS, Emery RW . Static or dynamic navigation for implant placement-choosing the method of guidance[J]. J Oral Maxillofac Surg, 2016,74(2):269-277. |
[5] | Wittneben JG, Gavric J, Belser UC , et al. Esthetic and clinical performance of implant-supported all-ceramic crowns made with prefabricated or CAD/CAM zirconia abutments: a randomized, multicenter clinical trial[J]. J Dent Res, 2017,96(2):163-170. |
[6] | Fürhauser R, Florescu D, Benesch T , et al. Evaluation of soft tissue around single-tooth implant crowns: the pink esthetic score[J]. Clin Oral Implants Res, 2005,16(6):639-644. |
[7] | Belser UC, Grütter L, Vailati F , et al. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores[J]. J Periodontol, 2009,80(1):140-151. |
[8] | 李晋蒙, 欧国敏 . 计算机辅助设计种植导板精确性及其影响因素[J]. 华西口腔医学杂志, 2017,35(1):93-98. |
Li JM, Ou GM . Accuracy of computer-guided implant placement and influencing factors[J]. West China J Stomatol, 2017,35(1):93-98. | |
[9] | Hu XL, Nahles S, Nelson CA , et al. Analysis of soft tissue display during enjoyment smiling. Part 1: caucasians[J]. Int J Periodont Restor Dent, 2013,33(1):e9-e15. |
[10] | Ahn HW, Moon SC, Baek SH . Morphometric evaluation of changes in the alveolar bone and roots of the maxillary anterior teeth before and after en masse retraction using cone-beam computed tomography[J]. Angle Orthod, 2013,83(2):212-221. |
[11] | Hiroya S . An application of dental implant on alveolar bone defect caused by injury: an esthetic recovery of anterior teeth region without a bone grafting[J]. Nihon Hotetsu Shika Gakkai Zasshi, 2005,49(3):510-511. |
[12] | Park SJ, Leesungbok R, Cui TX , et al. Reliability of a CAD/CAM surgical guide for implant placement: an in vitro comparison of surgeons’ experience levels and implant sites[J]. Int J Prosthodont, 2017,30(4):367-369. |
[13] | Vercruyssen M, Cox C, Coucke W , et al. A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template[J]. J Clin Periodontol, 2014,41(7):717-723. |
[14] | 金杭颖, 吴英浩, 徐继文 , 等. 国产数字化导板辅助上前牙种植手术的精准度研究[J]. 实用口腔医学杂志, 2018,34(5):644-647. |
Jin HY, Wu YH, Xu JW , et al. Precision evaluation of domestic digital guide assisting in the implantation of maxillary anterior teeth[J]. J Pract Stomatol, 2018,34(5):644-647. | |
[15] | Ramasamy M, Giri, Raja R , et al. Implant surgical guides: from the past to the present[J]. J Pharm Bioallied Sci, 2013,5(Suppl 1):S98-S102. |
[16] | Meloni SM, Tallarico M, De Riu G , et al. Guided implant surgery after free-flap reconstruction: four-year results from a prospective clinical trial[J]. J Craniomaxillofac Surg, 2015,43(8):1348-1355. |
[17] | Ozan O, Turkyilmaz I, Ersoy AE , et al. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement[J]. J Oral Maxillofac Surg, 2009,67(2):394-401. |
[18] | Tettamanti S, Millen C, Gavric J , et al. Esthetic evaluation of implant crowns and peri-implant soft tissue in the anterior maxilla: comparison and reproducibility of three different indices[J]. Clin Implant Dent Relat Res, 2016,18(3):517-526. |
[19] | Le BT, Borzabadi-Farahani A . Labial bone thickness in area of anterior maxillary implants associated with crestal labial soft tissue thickness[J]. Implant Dent, 2012,21(5):406-410. |
[20] | Jung MS, Lee SP, Kim GT , et al. Three-dimensional analysis of deciduous maxillary anterior teeth using cone-beam computed tomography[J]. Clin Anat, 2012,25(2):182-188. |
[21] | Choquet V, Hermans M, Adriaenssens P , et al. Clinical and radiographic evaluation of the papilla level adjacent to single-tooth dental implants. A retrospective study in the maxillary anterior region[J]. J Periodontol, 2001,72(10):1364-1371. |
[22] | Hultin M, Svensson KG, Trulsson M . Clinical advantages of computer-guided implant placement: a systematic review[J]. Clin Oral Implants Res, 2012,23(Suppl 6):124-135. |
[23] | Rungcharassaeng K, Caruso JM, Kan JY , et al. Accuracy of computer-guided surgery: a comparison of operator experience[J]. J Prosthet Dent, 2015,114(3):407-413. |
[24] | Cushen SE, Turkyilmaz I . Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in vitro study[J]. J Prosthet Dent, 2013,109(4):248-254. |
[1] | Wang Xudong, Wei Hongpu, Li Biao.. From “Empirical Surgery” to “Precision Surgery”: establishment and clinical application of precision orthognathic surgery system [J]. West China Journal of Stomatology, 2023, 41(5): 491-501. |
[2] | Zhang Junjing, Zhang Yuqiang, Fan Lin, Yu Haiyang.. Digital technology for fluid resin injection to close anterior diastema after orthodontic treatment [J]. West China Journal of Stomatology, 2023, 41(1): 114-122. |
[3] | Shi Zean, Xia Kai, Luo Liangyu, Zhao Zhihe, Liu Jun.. Three-dimensional finite element analysis of upper anterior teeth retraction and intrusion using clear aligners and mini-implants [J]. West China Journal of Stomatology, 2022, 40(5): 589-596. |
[4] | Yang Leining, Qin Hanglin, Zhang Jing, Han Xiaopeng. A case of precise prosthesis under the direction of target restoration space analysis after multidisciplinary combination therapy [J]. West China Journal of Stomatology, 2022, 40(5): 610-617. |
[5] | Gong Jinmei, Xia Xun, Hu Changqi, Huang Jiangqin, Guo Shuigen, Wei Hongwu.. Clinical observation of a narrow alveolar ridge in the anterior area with a simple taper retention implant [J]. West China Journal of Stomatology, 2022, 40(2): 175-182. |
[6] | Yao Jinfeng, Deng Mengzhao, Xie Tian, Chen Kan, Wang Qiuxu, Liang Zhigang.. Study on the application of oral digital design in aesthetic restoration of anterior teeth of cleft lip/palate patients [J]. West China Journal of Stomatology, 2021, 39(5): 582-590. |
[7] | Yu Haiyang. The question about the numerical value and quantitative data transfer of implant prosthodontics—orom experience guidance to digital guidance [J]. West China Journal of Stomatology, 2021, 39(4): 386-397. |
[8] | Zhang Yuqiang, Yu Haiyang. Interarch distance is a target restorative space value: clinical decisionmaking of implant restoration guided by measured value [J]. West China Journal of Stomatology, 2021, 39(2): 233-237. |
[9] | Liu Yunkun,Xu Xin,Zhou Xuedong. Potential application of human microbiomes in the diagnosis and treatment of type 2 diabetes mellitus [J]. West China Journal of Stomatology, 2019, 37(5): 556-562. |
[10] | Qintao Wang, Yumei Zhang. Collaboration from periodontics in the aesthetic restoration of anterior teeth [J]. West China Journal of Stomatology, 2017, 35(5): 453-455. |
[11] | Cheng Xingqun, Zhou Xuedong, Xu Xin. Application of saliva in disease diagnosis [J]. West China Journal of Stomatology, 2016, 34(6): 647-653. |
[12] | Li Xueyan, Deng Mengxuan, Yuan Xiaoping.. Stability of the anterior teeth and hard tissue of skeletal class Ⅲ malocclusion after orthodontic surgery: systematic review [J]. West China Journal of Stomatology, 2015, 33(3): 267-271. |
[13] | Jiang Chengcheng, Song Qinggao, He Wei, Chen Shang, Hong Tao.. Reliability of iWitness photogrammetry in maxillofacial application [J]. West China Journal of Stomatology, 2015, 33(3): 296-300. |
[14] | Xu Xin, Zheng Xin, Zheng Liwei, Cheng Lei, Zhou Xuedong.. Precision stomatology: current status and challenges [J]. West China Journal of Stomatology, 2015, 33(3): 315-321. |
[15] | Qi Jiani, Yue Lixin, Lan Jing. Research on gingival healing situation after stage Ⅱ surgery of dental implantation for periodontitis patients [J]. West China Journal of Stomatology, 2014, 32(2): 153-156. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||