华西口腔医学杂志 ›› 2018, Vol. 36 ›› Issue (3): 267-270.doi: 10.7518/hxkq.2018.03.007

• 临床研究 • 上一篇    下一篇

牙本质敏感影响程度量表简化版的验证性因素分析

李晓玲(), 王金华, 何松霖()   

  1. 1.重庆医科大学附属口腔医院,重庆 400015
    2.口腔疾病与生物医学重庆市重点实验室,重庆 400015
    3.重庆市高校市级口腔生物医学工程重点实验室,重庆 400015
  • 收稿日期:2017-07-23 修回日期:2018-02-06 出版日期:2018-06-01 发布日期:2018-06-01
  • 作者简介:

    李晓玲,护师,硕士,E-mail:490105210@qq.com

  • 基金资助:
    重庆高校创新团队建设计划资助项目(2016);重庆市高校市级口腔生物医学工程重点实验室资助项目(2016)

Confirmatory factor analysis of the shortened dentine hypersensitivity experience questionnaire

Xiaoling Li(), Jinhua Wang, Songlin He()   

  1. 1. College of Stomatology, Chongqing Medical University, Chong-qing 400015, China
    2. Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chong-qing 400015, China
    3.Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chong-qing 400015, China
  • Received:2017-07-23 Revised:2018-02-06 Online:2018-06-01 Published:2018-06-01
  • Supported by:
    Program for Innovation Team Building at Institutions of Higher Education in Chongqing (2016);;Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education (2016).

摘要:

目的 应用验证性因素分析考评牙本质敏感影响程度量表简化版(DHEQ-15)的三维维度结构。方法 采用DHEQ-15中文版对210名18~70岁牙本质敏感患者进行生活质量调查。应用验证性因素分析测试构建的量表三维模型的适切性。结果 回收有效量表210份。量表条目中“因牙齿敏感比其他人吃饭时间更长”得分最高。修正模型的主要指标中,卡方/自由度=2.213,拟合指数=0.905,调整拟合指=0.872,标准拟合指数=0.845,增量拟合指数=0.962,塔克-刘易斯指数=0.969,比较拟合指数=0.977,误差平方根近似值=0.068,均达到模型拟合标准。结论 含有三因子的结构模型与数据拟合度较好,证实DHEQ-15具有良好的结构效度,可在国内牙本质敏感患者中进一步推广应用。

关键词: 牙本质敏感影响程度量表, 维度, 验证性因素分析

Abstract:

Objective This review aims to identify the dimensional structure of the shortened dentine hypersensitivity experience questionnaire (DHEQ-15) using confirmatory factor analysis (CFA). Methods The Chinese language version of DHEQ-15 was applied to 210 patients with dentine hypersensitivity aged 18-70 years old. The three-dimensional construct was confirmed by CFA.Results All the questionnaires were fully completed. The item “Because of the sensations, I take longer to finish a meal than others” was the most frequently reported by the parents. The modified three-factor model is suitable for the data. The chi-square fit statistics/degree of freedom was 2.213, the goodness-of-fit index was 0.905, the adjusted goodness-of-fit index was 0.872, the normed fit index was 0.845, the incremental fit index was 0.962, the Tucker-Lewis index was 0.969, the comparative fit index was 0.977, and the root mean square error of approximation was 0.068. Conclusion Our findings generally support the three-dimensional construct of the DHEQ-15. Thus, DHEQ-15 can be used as a valid instrument in patients with dentine hypersensitivity in China.

Key words: dentine hypersensitivity experience questionnaire, dimensional structure, confirmatory factor analysis

中图分类号: