华西口腔医学杂志

• 临床研究 • 上一篇    下一篇

个性化钛网联合多孔高密度聚乙烯矫正眼眶骨折伴眼球内陷畸形

孙黎波1 肖金刚1, 2 兰玉燕2 熊义林3 张力1 周航宇1 张磊1   

  1. 1.泸州医学院附属口腔医院口腔颌面外科;2.口颌面修复重建和再生实验室;3.泸州医学院附属医院放射科,泸州 646000
  • 出版日期:2015-06-01 发布日期:2015-06-01
  • 通讯作者: 肖金刚,副教授,博士,E-mail:drxiaojg@sohu.com
  • 作者简介:孙黎波,硕士,E-mail:184466899@qq.com
  • 基金资助:

    国家自然科学基金资助项目(81371125);四川省科技厅基金资助项目(2014JY0044);四川省教育厅基金资助项目(10ZB030,15ZB0167)

Reconstruction of the orbital fracture with enophthalmos using customized titanium mesh combined with Medpor

Sun Libo1, Xiao Jingang1,2, Lan Yuyan2, Xiong Yilin3, Zhang Li1, Zhou Hangyu1, Zhang Lei1.   

  1. 1. Dept. of Oral and Maxillofacial Surgery, Hospital of Stomatology, Luzhou Medical College, Luzhou 646000, China; 2. Orofacial Reconstruction and Regeneration Laboratory, Hospital of Stomatology, Luzhou Medical College, Luzhou 646000, China; 3. Dept. of Radiology, Affiliated Hospital, Luzhou Medical College, Luzhou 646000, China
  • Online:2015-06-01 Published:2015-06-01

摘要:

目的 应用镜像与快速成型技术制作个性化钛网重建眼眶,在钛网上植入多孔高密度聚乙烯(Medpor)矫正眼球内陷,评价其治疗效果。方法 对18例眼眶骨折患者术前行眼眶轴位、冠状位及矢状位CT扫描及三维重建,以CT数据为基础,应用快速成型技术制备实体模型,在其上制作个性化预成形钛网,术中植入钛网行眼眶重建,并在钛网基础上充填Medpor矫正眼球内陷。术后复查眼眶CT,检查钛网植入位置、眼及面部外形和眼功能。结果术后复查CT,18例患者的个性化预成形钛网均能精确地重建骨折的眼眶,眼及面部外形和眼功能显著恢复。术中术后均未发生严重并发症。结论 基于镜像与快速成型技术的个性化预成形钛网技术可以精确地重建骨折及伴有骨缺损的眼眶,在钛网上植入Medpor可有效矫正眼球内陷及眼球下移畸形。

关键词: 眼眶骨折, 眼球内陷, 镜像, 个性化钛网

Abstract:

Objective  This study aims to evaluate the effect of customized titanium mesh, which was designed by mirror imaging and rapid prototyping technique, with Medpor applied for orbital fracture with enophthalmos. Methods  Orbital axial, coronal, and sagittal CT scan, and three-dimension CT examination were performed routinely in 18 cases of orbital fracture with enophthalmos preoperatively. Based on the CT data, prosthesis model was designed by reverse engineering and rapid prototyping technique. The customized titanium mesh and Medpor were applied for orbital reconstruction and enophthalmos correction. Orbital reduction and globe projection were evaluated by postoperative CT scan and clinical follow-up visits. Results  CT scans revealed that the customized titanium mesh with Medpor had great accuracy to reconstruct the orbital fracture and correct the enophthalmos in all patients without serious complications. The eye and facial appearance and function recovered significantly. No serious complication occurred in the operation and after operation. Conclusion  The customized titanium mesh, based on mirror imaging and rapid prototyping technique, can accurately reconstruct the orbital fractures with enophthalmos. The application of Medpor can effectively correct enophthalmos and eyeball mobility malformation.

Key words: orbital fracture, enophthalmos, mirror imaging, customized titanium mesh